Roof systems 3 1 3 4 lumber rafters.
Roof diaphragm aspect ratio.
Gypsum board diaphragm ceilings shall be in accordance with section 2508 5.
Wood diaphragm chords aspect ratios hokie66 structural 2 jan 11 14 56 when it gets too complicated to brace at the roof level brace at the ceiling level.
2306 2 3 double diagonally sheathed lumber diaphragms.
But i can t find any similar limit for metal deck.
Jump to full code chapter.
The sdi diaphragm design manual third edition is an excellent design reference every engineer should utilize if designing with steel deck diaphragms.
Similar changes to 2306 3 for shear walls.
2306 2 4 gypsum board diaphragm ceilings.
The dimensions of the case study diaphragm were 192 ft x 96 ft.
Roof diaphragm aspect ratio table 3 16a1 l.
I know for plywood diaphragms the codes limit it to 4 1 aspect ratio.
Diaphragm aspect ratio is ok.
2305 2 3 diaphragm aspect ratios.
Size and shape of diaphragms shall be limited as set forth in table 2305 2 3.
3 amongst all the models only four storey building with 1 4 aspect ratio has flexibility ratio greater than 1 5 so it s.
Aspect ratios of 2 1 and 1 2.
2 since flexibility ratio increases with increase in aspect ratio of building we can say that flexibility of diaphragm increases with increase in aspect ratio.
The manual includes pertinent design information considerations fastener information deck shear capacity tables and a plethora of highly relevant design examples stepping you through all the intricate details and covering nearly any.
Rafter span horizontal projection 26 16 rafter spacing 24 16 eave overhang length lesser of 2 or rafter length 3 2 rake overhang length lesser of 2 or outlooker length 2 2 roof slope 1 5 12 12 7 12 roof diaphragms.
The corresponding diaphragm chord forces are therefore equal to m divided by the diaphragm depth b.
Double diagonally sheathed lumber diaphragms shall be designed and constructed in accordance with af pa sdpws.
Twelve large diaphragm models were created to investigate the influences of various modeling and.
Behavior of a case study all wood panelized roof diaphragm.
Diaphragm aspect ratios sdpws table 4 2 4 type maximum length width ratio for an 84 x 34 diaphragm the aspect ratio is 2 5 3.
Analyses were performed for both loads applied in the longitudinal and transverse directions i e.
The maximum unit shear on the wall diaphragm is also equal to the roof reaction r divided by b.
There is a discussion going between the engineers in my office about the acceptibility of a 4 3 1 roof diaphragm.
Min 12 7 and l.